VMS Help SHOW, PRINTER, Examples *Conan The Librarian |
1.$ SHOW PRINTER LPA0:
Printer LPA0:, device type LP11, is online, allocated, spooled
Error count 0 Operations completed 880
Owner process "SYMBIONT_0001" Owner UIC [0,0]
Owner process ID 21C0008D Dev Prot S:RWLP,O:RWLP,G:RWLP,W:RWLP
Reference count 2 Default buffer size 132
Page width 132 Page Length 66
No Carriage_return Formfeed Lowercase
No Passall No Wrap Printall
No Fallback No Tab Truncate
No Sixels No Bitmapped No Polled
Unidirectional
Intermediate device: STAR$DUA1:
Associated queue: LN01$PRINT
The SHOW PRINTER command in this example displays the settings
for the printer LPA0.
2.$ SHOW PRINTER LPA0/IDSTRING
Printer LPA0:, device type PC printer, is online, record-oriented device,
carriage control.
Error count 0 Operations completed 0
Owner process "" Owner UIC [SYSTEM]
Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
Reference count 0 Default buffer size 132
Page width 132 Page Length 66
No Carriage_return Formfeed Uppercase
No Passall No Wrap No Printall
No Fallback No Tab Truncate
No Sixels No Bitmapped Polled
Unidirectional
IDString:
MFG: HEWLETT-PACKARD;
MDL: DESKJET 895C;
CMD: MLC,PCL,PML;
CLASS: PRINTER;
DESCRIPTION: Hewlett-Packard DeskJet 895C;
SERN: MX88P2V0VWGO;
VSTATUS: $HB0$FC0,ff,DN,IDLE,CUT;
The SHOW PRINTER/IDSTRING command in this example displays the
ID string for the printer LPA0.
3.$ SHOW PRINT LPA0/IDSTRING
Printer LRA0:, device type LP11, is online, record-oriented device,
carriage control.
Error count 0 Operations completed 0
Owner process "" Owner UIC [SYSTEM]
Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
Reference count 0 Default buffer size 132
Page width 132 Page Length 66
No Carriage_return Formfeed Uppercase
No Passall No Wrap No Printall
No Fallback No Tab Truncate
No Sixels No Bitmapped No Polled
Unidirectional
%SYSTEM-F-DEVOFFLINE, device is not in configuration or not available
If the device has been disconnected and marked offline, the
SHOW PRINTER/IDSTRING command displays this information.
If the attempt to read the ID string should fail (for an
unknown reason other than device disconnection), the reference
to the ID string appears as:
%SHOW-W-NOIDSTRING, ID String could not be retrieved
4.$ SHOW PRINT LPA0/SERIALNUM
Printer LPA0:, device type PC printer, is online, record-oriented device,
carriage control.
Error count 0 Operations completed 0
Owner process "" Owner UIC [SYSTEM]
Owner process ID 00000000 Dev Prot S:RWPL,O:RWPL,G,W
Reference count 0 Default buffer size 132
Page width 132 Page Length 66
No Carriage_return Formfeed Uppercase
No Passall No Wrap No Printall
No Fallback No Tab Truncate
No Sixels No Bitmapped Polled
Unidirectional
Serial Number: MX88P2V0VWGO
The SHOW PRINTER/SERIALNUM command in this example displays the
serial number for the printer LPA0.
If the device has been disconnected and marked offline, the
SHOW PRINTER/SERIALNUM command replaces the reference to the
serial number with the following message:
%SYSTEM-F-DEVOFFLINE, device is not in configuration or not available
If the ID string is not supported by the USB printer in
question, the reference to the ID string will appear as:
%SHOW-W-NOSERIALNUM, Serial number could not be retrieved
|
|