VMS Help Sys Parameters, MPW_WAITLIMIT *Conan The Librarian |
MPW_WAITLIMIT sets the number of pages on the modified-page list
that causes a process to wait until the next time the modified-
page writer writes the modified list. This parameter limits the
rate at which any single process can produce modified pages. If
this value is less than MPW_HILIMIT, a system deadlock occurs.
The value for this parameter is normally equal to MPW_HILIMIT.
MPW_WAITLIMIT has the AUTOGEN and DYNAMIC attributes.
|
|