The MACRO Compiler for OpenVMS Systems supports most of the
standard VAX MACRO assembler directives discussed in the VAX
MACRO and Instruction Set Reference Manual. However, some
directives that are supported by the VAX MACRO assembler do not
make sense for compiled code. Consequently, the compiler flags
them and continues execution. You can disable the flagging of
these directives by specifying /NOFLAG=DIRECTIVES.
The directives that you can disable are:
o .ENABLE and .DISABLE ABSOLUTE-for forcing absolute addressing
modes
o .ENABLE and .DISABLE TRUNCATION-for enabling floating point
truncation
o .LINK-for specifying linker options in a linker options file
o .DEFAULT-for setting displacement lengths
o .OPDEF and .REFn-for defining opcodes
o Alignment directives (.ALIGN, .EVEN, and .ODD) in code psects
o .TRANSFER
o .MASK
NOTE
The length of the argument to a .ASCID directive is limited
to 996 characters when using the MACRO Compiler for OpenVMS
Systems. No such restriction exists in the VAX MACRO