VMS Help CRTL, ualarm, Description *Conan The Librarian |
The ualarm function causes the SIGALRM signal to be generated for
the calling process after the number of real-time microseconds
specified by useconds has elapsed. When the interval argument is
nonzero, repeated timeout notification occurs with a period in
microseconds specified by interval. If the notification signal
SIGALRM is not intercepted or is ignored, the calling process is
terminated.
If you call a combination of ualarm and setitimer functions, and
the AST status is disabled, the return value is invalid.
If you call a combination of ualarm and setitimer functions, and
the AST status is enabled, the return value is valid.
This is because you cannot invoke an AST handler to clear the
previous value of the timer when ASTs are disabled or invoked
from a handler that was invoked at AST level.
NOTE
Interactions between ualarm and either alarm, or sleep are
unspecified.
See also setitimer.
|
|